3.5. Evaluation Software
Important
Instrument not compatible with elder software versions!
Use HYDROcom 6 with at least version 6.3.0.20 for the communication
with the MultiSystem 4010. Otherwise the measuring data cannot be
transferred correctly. The current version is contained on the data CD of
your instrument or in the dowload section of www.hydrotechnik.com.
The evaluation software HYDROcom is part of the delivery. After transfering the measuring data to a
PC you may use the application to evaluate, process and present them.
3.6. Technical Data
Casing ABS plastic
Weight 841 g
Protection type IP40
CE-label complies with EN 50 081-1 and EN 50082-1 – RoHS
Power supply internally: NiMh batteries, 14.4V / 2,150 mAh;
externally: 24 V DC / 630 mA
Dimensions 225 x 123 x 60 mm (L x W x H)
Interfaces USB 2.0, CAN, RS232
Environmental temperature 0 … +45 °C
Relative humidity 0 … 80% (not condensing)
Storage temperature -20 … +50 °C
Value display 5 digit
Trigger channel, key
Scan rate settable from 1 ms to 999 min
Measuring rate 1 ms (1 kHz)
Memory SD carde 2 GB, max. 100 measuring series
max. 4 MB / measuring series (1 million values)
Error limits analog: ± 0.2% of final value; digital: ± 0.02 % of measured value